<Error>
<ErrorNumber>11005</ErrorNumber>
<ErrorFamily>Cable Disconnected</ErrorFamily>
<ErrorMessage>
CABLE: External Chiller/Debris Blower sensor cable disconnected.
</ErrorMessage>
<AppliesTo>
<UnnumberedList>
<ListItem><Text>Trendsetter_400/800</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_Auto</Text></ListItem>
<ListItem><Text>Trendsetter_400/800_Proofing</Text></ListItem>
</UnnumberedList>
</AppliesTo>
<ServiceInformation>
<DescriptionText><text>
The firmware cannot detect the cable running to the chiller or the blower.  If both
devices are installed, the cable will be daisy-chained between them, so both must be checked.
</text></DescriptionText>
<DescriptionText><text>
If the device is an MPE Trendsetter with an internal heat exchanger, please verify that
'set sys chin' is set to zero.
</text></DescriptionText>
</ServiceInformation>
<OperatorAction>
<DescriptionText><text>
</text></DescriptionText>
</OperatorAction>
<Cause>
The cable really is disconnected, or there is an intermittent connection.
</Cause>
<SeeAlso>
<UnnumberedList>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 0 Error Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 0 Command Index</LinkTitle></Link>
<Link><LinkAddress>..\..\ShowAllNVS.htm</LinkAddress><LinkTitle>Firmware 0 NVS Index</LinkTitle></Link>
</OtherLinks>
<Updated>
Updated: Wed Jul 16 19:32:31 2008 PST
</Updated>
<Links>
</Links>
</Error>